For more information on publications, visit our Education.section.
Nitinella Plus / Nitinella Plus – B
- Home
- GASTROENTEROLOGY
- Biliary stents
- Nitinella Plus / Nitinella Plus – B
Are you interested
in this
product?
Nitinella Plus / Nitinella Plus – B
Personal references
Assoc. Prof. Jan Trna, MD, Ph.D.
Department of Advanced Digestive Endoscopy, Masaryk Memorial Cancer Institute, Czech Republic
All the stents were successfully deployed, without major complications, almost zero migration and long patency.
The stents are nicely visible under x-ray and sufficiently open the strictures. The delivery systems are reliable and easy to manipulate.
It is my pleasure to recommend Ella stents.”
Antonio Pinar Ruiz, MD
Vascular and Interventional Radiology, Hospital General de Ciudad Real, Spain
Very flexible delivery system and its great navigability.
Ideal for treating stenosis located in the common bile duct and common hepatic duct."
Basic description
The Nitinella Plus is a self-expandable nitinol biliary stent that can be implanted endoscopically or transhepatically and is available as uncovered (Nitinella Plus – B) or partially or fully covered with silicone. Due to the significant radiopaque markers, the product is perfectly visible during implantation and during subsequent X-ray examinations.
Indication
The Nitinella Plus and Nitinella Plus – B are indicated for the palliative treatment of biliary strictures caused by malignant neoplasms.
Features / Benefits
Significant radiopaque markers made of thick-walled Pt / Ir tubes at both ends and in the middle of the stent allow easy visibility of the stent during insertion.
The high flexibility of the stent keeps the lumen open even if placed in anatomical curves. The atraumatic stent ends do not irritate the bile duct wall.
Reinforced braiding at the stent ends – designed to reduce the risk of migration.
The durable silicone covering covers the outer and inner surfaces of the stent and prevents tissue ingrowth.
The delivery system with braided sheath is kink-resistant. Its design allows the stent to be retracted back up to 50% of the stent length.
MRI compatibility – “MR Conditional”, compatible with 1.5 Tesla and 3 Tesla static magnetic field.
Patent protected
Implantation
The stent is delivered sterile compressed in a delivery system. We recommend using a 0.035 ”(0.89 mm) stiff guidewire for the implantation.
Available sizes
Endoscopic delivery system – 175 cm | |||||
---|---|---|---|---|---|
Stent diameter [mm] | Stent length [mm] | Delivery system diameter [F] | Nitinella Plus – B Uncovered stent | Nitinella Plus Partially covered stent | Nitinella Plus Fully covered stent |
REF | |||||
8 | 40 | 7 F for uncovered 9 F for covered |
019-01B-08-040 | 019-01C-08-040 | 019-01D-08-040 |
60 | 019-01B-08-060 | 019-01C-08-060 | 019-01D-08-060 | ||
80 | 019-01B-08-080 | 019-01C-08-080 | 019-01D-08-080 | ||
100 | 019-01B-08-100 | 019-01C-08-100 | 019-01D-08-100 | ||
10 | 40 | 7 F for uncovered 9 F for covered stenty |
019-01B-10-040 | 019-01C-10-040 | 019-01D-10-040 |
60 | 019-01B-10-060 | 019-01C-10-060 | 019-01D-10-060 | ||
80 | 019-01B-10-080 | 019-01C-10-080 | 019-01D-10-080 | ||
100 | 019-01B-10-100 | 019-01C-10-100 | 019-01D-10-100 |
Transhepatic delivery system – 60 cm | |||||
---|---|---|---|---|---|
Stent diameter [mm] | Stent length [mm] | Delivery system diameter [F] | Nitinella Plus – B Uncovered stent | Nitinella Plus Partially covered stent | Nitinella Plus Fully covered stent |
REF | |||||
8 | 40 | 7 F for uncovered 9 F for covered |
019-01B-08-040-T | 019-01C-08-040-T | 019-01D-08-040-T |
60 | 019-01B-08-060-T | 019-01C-08-060-T | 019-01D-08-060-T | ||
80 | 019-01B-08-080-T | 019-01C-08-080-T | 019-01D-08-080-T | ||
100 | 019-01B-08-100-T | 019-01C-08-100-T | 019-01D-08-100-T | ||
10 | 40 | 7 F for uncovered 9 F for covered |
019-01B-10-040-T | 019-01C-10-040-T | 019-01D-10-040-T |
60 | 019-01B-10-060-T | 019-01C-10-060-T | 019-01D-10-060-T | ||
80 | 019-01B-10-080-T | 019-01C-10-080-T | 019-01D-10-080-T | ||
100 | 019-01B-10-100-T | 019-01C-10-100-T | 019-01D-10-100-T |
Leaflets
NITINELLA PLUS
(PDF)
Publications
Covered versus uncovered self-expandable nitinol stents in the palliative treatment of malignant distal biliary obstruction: results from a randomized, multicenter study
Kullman E, Frozanpor F, Söderlund C, Linder S, Sandström P, Lindhoff-Larsson A, Toth E, Lindell G, Jonas E, Freedman J, Ljungman M, Rudberg C, Ohlin B, Zacharias R, Leijonmarck CE, Teder K, Ringman A, Persson G, Gözen M, Eriksson O.
Gastrointest Endosc. 2010 Nov;72(5):915-23. doi: 10.1016/j.gie.2010.07.036. PMID: 21034892.
Use of fully covered self-expanding metal stents in benign biliary diseases
García-Cano J
World J Gastrointest Endosc. 2012 Apr 16;4(4):142-7. doi: 10.4253/wjge.v4.i4.142. PMID: 22523615; PMCID: PMC3329614.
Biliary stents: models and methods for endoscopic stenting
Dumonceau JM, Heresbach D, Devière J, Costamagna G, Beilenhoff U, Riphaus A; European Society of Gastrointestinal Endoscopy
Endoscopy. 2011 Jul;43(7):617-26. doi: 10.1055/s-0030-1256315. Epub 2011 May 25. PMID: 21614754.