Productos - Ella CS

Productos

Nitinella Plus / Nitinella Plus - B

Ella

Referencias personales

Assoc. Prof. Jan Trna, MD, Ph.D.

Department of Advanced Digestive Endoscopy, Masaryk Memorial Cancer Institute, Czech Republic

“These stents represent substantial part of all biliary stents used in our department and in the last 4 years we have used more than 120 pcs of these biliary stents.
All the stents were successfully deployed, without major complications, almost zero migration and long patency.
The stents are nicely visible under x-ray and sufficiently open the strictures. The delivery systems are reliable and easy to manipulate.
It is my pleasure to recommend Ella stents.”

Antonio Pinar Ruiz, MD

Vascular and Interventional Radiology, Hospital General de Ciudad Real, Spain

"Its design adapts perfectly to anatomical structures.
Very flexible delivery system and its great navigability.
Ideal for treating stenosis located in the common bile duct and common hepatic duct."

Descripción básica

La Nitinella Plus es una prótesis biliar de nitinol autoexpandible que se puede implantar por vía endoscópica o transhepática y está disponible como sin cubierta (Nitinella Plus - B) o parcialmente o totalmente cubierta de silicona. Debido a los importantes marcadores radiopacos, el producto es perfectamente visible durante la implantación y durante los exámenes radiográficos posteriores.

Indicaciones

La Nitinella Plus y la Nitinella Plus - B están indicadas para el tratamiento paliativo de las estenosis biliares causadas por neoplasias malignas.

Características / Beneficios

Los marcadores radiopacos significativos hechos de tubos de Pt/Ir de paredes gruesas en ambos extremos y en el punto medio de la prótesis, permiten una fácil visibilidad de la prótesis durante la inserción.
La alta flexibilidad de la prótesis mantiene el lumen abierto incluso si se coloca en curvas anatómicas. Los extremos atraumáticos de la prótesis no irritan la pared del conducto biliar.
La malla reforzada en los extremos de la prótesis reduce el riesgo de migración.
La cubierta de silicona durable cubre las superficies exterior e interior de la prótesis y evita el sobrecrecimiento de tejido.
El sistema de implantación con vaina trenzada es resistente a las torceduras. Su diseño permite que la prótesis se retraiga hasta el 50% de la longitud de la prótesis.
Compatibilidad con IRM: "MR condicional", compatible con campo magnético estático de 1,5 Tesla y 3 Tesla.

Protegido por patente

Implantación

La prótesis se entrega estéril y comprimida en el sistema de implantación. Recomendamos utilizar un alambre guía rígido de 0,035”(0,89 mm) para la implantación.

Nitinella Plus - 3D animación

Medidas disponibles

Sistema de implantación endoscópica - 175 cm
Diámetro de la prótesis
[mm]
Longitud de la prótesis
[mm]
Diámetro del sistema de implantación
[F]
Nitinella Plus - B
Prótesis sin cubierta
Nitinella Plus
Prótesis parcialmente cubierta
Nitinella Plus
Prótesis totalmente cubierta
REF
8 40 7 para
no cubierto 
9 para
recubierto
019-01B-08-040 019-01C-08-040 019-01D-08-040
60 019-01B-08-060 019-01C-08-060 019-01D-08-060
80 019-01B-08-080 019-01C-08-080 019-01D-08-080
100 019-01B-08-100 019-01C-08-100 019-01D-08-100
10 40 7 para
no cubierto 
9 para
recubierto
019-01B-10-040 019-01C-10-040 019-01D-10-040
60 019-01B-10-060 019-01C-10-060 019-01D-10-060
80 019-01B-10-080 019-01C-10-080 019-01D-10-080
100 019-01B-10-100 019-01C-10-100 019-01D-10-100
Sistema de implantación transhepática - 60 cm
Diámetro de la prótesis
[mm]
Longitud de la prótesis
[mm]
Diámetro del sistema de implantación
[F]
Nitinella Plus - B
Prótesis sin cubierta
Nitinella Plus
Prótesis parcialmente cubierta
Nitinella Plus
Prótesis totalmente cubierta
REF
8 40 7 para
no cubierto 
9 para
recubierto
019-01B-08-040-T 019-01C-08-040-T 019-01D-08-040-T
60 019-01B-08-060-T 019-01C-08-060-T 019-01D-08-060-T
80 019-01B-08-080-T 019-01C-08-080-T 019-01D-08-080-T
100 019-01B-08-100-T 019-01C-08-100-T 019-01D-08-100-T
10 40 7 para
no cubierto 
9 para
recubierto
019-01B-10-040-T 019-01C-10-040-T 019-01D-10-040-T
60 019-01B-10-060-T 019-01C-10-060-T 019-01D-10-060-T
80 019-01B-10-080-T 019-01C-10-080-T 019-01D-10-080-T
100 019-01B-10-100-T 019-01C-10-100-T 019-01D-10-100-T

Publicaciones

Covered versus uncovered self-expandable nitinol stents in the palliative treatment of malignant distal biliary obstruction: results from a randomized, multicenter study

Kullman E, Frozanpor F, Söderlund C, Linder S, Sandström P, Lindhoff-Larsson A, Toth E, Lindell G, Jonas E, Freedman J, Ljungman M, Rudberg C, Ohlin B, Zacharias R, Leijonmarck CE, Teder K, Ringman A, Persson G, Gözen M, Eriksson O.

Gastrointest Endosc. 2010 Nov;72(5):915-23. doi: 10.1016/j.gie.2010.07.036. PMID: 21034892.

Use of fully covered self-expanding metal stents in benign biliary diseases

García-Cano J

World J Gastrointest Endosc. 2012 Apr 16;4(4):142-7. doi: 10.4253/wjge.v4.i4.142. PMID: 22523615; PMCID: PMC3329614.

Biliary stents: models and methods for endoscopic stenting

Dumonceau JM, Heresbach D, Devière J, Costamagna G, Beilenhoff U, Riphaus A; European Society of Gastrointestinal Endoscopy

Endoscopy. 2011 Jul;43(7):617-26. doi: 10.1055/s-0030-1256315. Epub 2011 May 25. PMID: 21614754.

Para obtener más información sobre publicaciones, visite nuestra sección de Educación.

Aviso

La información de este sitio web está destinada a los profesionales de la salud. Al hacer clic en Intro, usted confirma que es un profesional de la salud.

Al hacer clic en Dejar será redirigido a la página de Contacto donde encontrará los datos de contacto de nuestra empresa.